DC - 11.00 GHz
Specifications
Cable Code Standard 21
Armored None
Frequency Range DC - 11.00 GHz
Outer Diameter [mm] 10.80
Impedance [Ohms]
(@ sea level and +25°C)
50 ± 2
Velocity of Propagation
[%, ± 2%]
66.00
Capacitance [pF/m] 106.00
Dielectric Strength
(60 Hz) [KV rms]
10.00
Max. Operating Voltage
(60 Hz, @ sea level) [KV rms]
3.70
Nominal Insertion Loss vs. Frequency [dB/m] 0.50 GHz 0.25
2.00 GHz 0.62
4.00 GHz 1.05
8.00 GHz 1.64
10.00 GHz 1.87
Nominal CW Power vs. Frequency
(@ sea level and +20°C)
[Watts]
0.50 GHz 300.00
2.00 GHz 110.00
4.00 GHz 64.00
8.00 GHz 38.00
10.00 GHz 32.00
RF Leakage @ 9.5 GHz -90 dBC @ 10.0 GHz dbC
Operating Temperature Range -40 to +85
Center Conductor Material Stranded silver-plated copper
Diameter [mm] 2.25
Dielectric Material PE
Diameter [mm] 7.20
Dielectric Constant 2.3
Outer Conductor Construction 2x silver-plated copper braid
Outer Jacket PVC
Weight [grams/m] 185.00
Connector Retention Force [N] -
Minimum Bend Radius, Inside, Static [mm] 55.00
Minimum Bend Radius, Inside, Dynamic [mm] 165.00
Cross Section View:
Cable Cross Section View

 

Attenuation & Power Graph:
Graph

Spectrum Elektrotechnik GmbH | Olschewskibogen 1 | 80935 Munich, Germany
www.spectrum-et.com | sales@spectrum-et.com | +49 (0)89 / 354 804-0 | +49 (0)89 / 354 804-90
Specifications are subject to change without notice.