Cable Datasheets


Commercial RG Cable
Cable Type 74
DC - 1.00 GHz
Specifications
Cable Code Standard 74
Armored None
Frequency Range DC - 1.00 GHz
Outer Diameter [mm] 2.80
Impedance [Ohms]
(@ sea level and +25°C)
50 ± 2
Velocity of Propagation
[%, ± 2%]
65.90
Capacitance [pF/m] 105.00
Dielectric Strength
(60 Hz) [KV rms]
2.00
Max. Operating Voltage
(60 Hz, @ sea level) [KV rms]
1.10
Nominal Insertion Loss vs. Frequency [dB/m] 0.20 GHz 0.56
0.50 GHz 0.92
0.80 GHz 1.31
1.00 GHz 1.48
Nominal CW Power vs. Frequency
(@ sea level and +20°C)
[Watts]
0.20 GHz 38.00
0.50 GHz 23.00
0.80 GHz 19.00
1.00 GHz 17.00
RF Leakage @ 9.5 GHz -80 dBC @ 1.0 GHz dbC
Operating Temperature Range -40 to +85
Center Conductor Material Stranded (7x 0.16 mm) copper covered steel
Diameter [mm] 0.48
Dielectric Material PE
Diameter [mm] 1.52
Dielectric Constant 2.3
Outer Conductor Construction tin-plated copper braid
Outer Jacket PVC
Weight [grams/m] 14.00
Connector Retention Force [N] -
Minimum Bend Radius, Inside, Static [mm] 24.00
Minimum Bend Radius, Inside, Dynamic [mm] 60.00
Cross Section View:
Cable Cross Section View

 

Attenuation & Power Graph:
Graph

Spectrum Elektrotechnik GmbH | Olschewskibogen 1 | 80935 Munich, Germany
www.spectrum-et.com | sales@spectrum-et.com | +49 (0)89 / 354 804-0 | +49 (0)89 / 354 804-90
Specifications are subject to change without notice.